What are the causes and solutions for severe wear of the balance disc in a multistage centrifugal pump?
Nov 25, 2025
Leave a message
Many multistage centrifugal pumps rely on balancing discs to balance axial forces. While these discs offer the advantage of automatic axial force balancing, they are also prone to wear. Problems with the balancing disc can lead to decreased pump efficiency, vibration, overcurrent, insufficient output, and in severe cases, pump failure. Because many maintenance personnel lack understanding of balancing disc devices, pumps with such problems often require repeated repairs, increasing maintenance costs and potentially causing equipment downtime. Therefore, understanding common balancing disc malfunctions and their solutions is essential.

Common causes of wear on the balance disc of a multistage centrifugal pump
(1)Balancing water pipe blockage:
If the balancing water pipe is blocked, p6 will equal p4, meaning the balancing disc can no longer generate balancing force and has lost its function. In this case, the axial force on the pump will cause severe friction on the balancing disc, which may prevent the pump from running or even burn out the motor. Balancing water pipe blockage is the easiest fault to resolve, but it is also the most common. For maintenance personnel, when encountering a balancing device malfunction, the first thing to check is whether the balancing water pipe is clear. Our company has had an example where maintenance personnel failed to detect a blockage in the balancing water pipe, resulting in the replacement of three sets of balancing discs and balancing rings. This not only failed to solve the problem but also burned out two motors. Finally, after discovering the problem, replacing a single balancing water pipe solved it.
(2) Non-compliant part shape tolerances:
Due to the high precision requirements of the balancing disc and balancing ring, problems are generally rare. However, the discharge section, which is assembled with the balancing ring, frequently exhibits non-compliant behavior. Many multi-stage pumps have seized upon startup, despite inspection revealing unobstructed balancing water pipes, a balancing disc, and a balancing ring. The root cause was found to be an excessively vertical misalignment of the balancing ring in the discharge section, leading to uneven gaps between the balancing ring and the balancing disc, causing the balancing device to malfunction. If the problem lies with the discharge section, it is best to replace it.
(3) Pressure leakage from behind the balancing ring:
Since the balancing ring and discharge section are connected by screws, uneven tightening or a loose connection can cause pressure leakage. This leakage results in insufficient balancing force, causing the balancing disc to grind. To check for pressure leakage, inspect the junction of the balancing ring and discharge section for signs of high-pressure water erosion. If present, remove these signs and reinforce the seal with O-rings. Ensure all fixing screws are tightened evenly.
(4) Excessive wear of the balance sleeve and shaft sleeve leading to excessive clearance b1:
Theoretically, a larger clearance b1 would be more conducive to pushing open the balance disc, but this would increase leakage and reduce efficiency. However, in actual pump operation, if b1 is greater than 0.6, the balance disc's effect deteriorates. I believe this is because when b1 is greater than 0.6, the leakage is too large, resulting in the balance water pipe not having enough capacity to draw so much water to the suction inlet, thus causing p6 to rise. Since the pressure difference between p4 and p6 decreases, the balance disc device fails. Therefore, b1 should be kept between 0.3 and 0.5.
(5) Use in frequently opened/closed applications:
Because the balance disc device has the characteristic of friction during opening, this structure is not suitable for frequently opened/closed applications. The only options are to change the balancing method, replace the pump with another model, or change the system's operating conditions.
Multistage centrifugal pump balance disc maintenance method
1. During routine inspections, check if the pump balance pipe is blocked.
2. Check if the rotor displacement exceeds the standard.
3. Check the wear of the balance disc and balance ring every six months.
4. Replace the entire balance disc assembly annually.
Sometimes, due to urgent on-site situations, it is necessary to repair worn balance discs and balance rings (parts take a long time to arrive from the pump manufacturer). Here's a repair method: The worn end faces can be machined flat on a lathe, with the machining allowance as small as possible. Ensure both end faces are perpendicular to the axis, and the surface finish should ideally be within Ra32. After machining, measure the axial dimension and compare it to the original design dimension (which can be obtained from the manufacturer). Machine a flat washer using the reduced axial dimension (preferably machined by wire cutting to ensure balance at both ends) and install it behind the balance ring. This ensures the axial dimension matches the original design, preventing misalignment between the impeller and guide vane. This method allows the pump to operate temporarily, but it must be replaced promptly with a new part, as this increases the risk of pressure leakage behind the balance ring.
To reduce wear on the balance disc of a multistage centrifugal pump, we can take the following steps. First, select suitable materials and perform proper surface treatment to improve the wear resistance of the balance disc. Second, choose appropriate operating conditions to avoid excessive vibration and the ingress of solid particles. Finally, strengthen maintenance, regularly inspect and replace severely worn balance discs to ensure the normal operation of the pump.